[vc_row full_width=”stretch_row_content_no_spaces” woodmart_stretch_content=”section-stretch-content-no-pd” woodmart_css_id=”64a5af7baade4″ responsive_spacing=”eyJwYXJhbV90eXBlIjoid29vZG1hcnRfcmVzcG9uc2l2ZV9zcGFjaW5nIiwic2VsZWN0b3JfaWQiOiI2NGE1YWY3YmFhZGU0Iiwic2hvcnRjb2RlIjoidmNfcm93IiwiZGF0YSI6eyJ0YWJsZXQiOnt9LCJtb2JpbGUiOnt9fX0=” mobile_bg_img_hidden=”no” tablet_bg_img_hidden=”no” woodmart_parallax=”0″ woodmart_gradient_switch=”no” woodmart_box_shadow=”no” wd_z_index=”no” woodmart_disable_overflow=”0″ row_reverse_mobile=”0″ row_reverse_tablet=”0″][vc_column][vc_single_image image=”10181″ img_size=”full” alignment=”center” parallax_scroll=”no” woodmart_inline=”no”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text woodmart_inline=”no” text_larger=”no”]

شرکت نیک نیرو توسعه فردا در زمینه طراحی و تامین انواع سوئیچگیرهای برق در سطوح ولتاژ 400VAC, 230VAC, 690VAC و 48VDC, 110VDC  مشغول به فعالیت می باشد.این شرکت علاوه بر طراحی مدارک مربوط به انواع تابلوهای صنایع وزارت نیرو، پروژه های صنایع نفت، گاز و پتروشیمی را نیز انجام می دهد با اتکا به دانش فنی توسط مهندسین مجرب این شرکت، طراحی و تامین انواع تابلوهای فشار ضعیف کشویی اعم از کشویی AC و کشویی موتوری (MCC) و فیکس صورت می گیرد. برخی از مدارکی که توسط این شرکت طراحی می گردند، به شرح ذیل می باشند:

 

LV PART
General
Vendor Print Index & Schedule
Quality Control Plan/Quality Control System
Packing/Painting/Shop test & Inspection Procedure/Site Acceptance Tests Procedure
Sub Vendor List
Time Schedule/Progress Report
Inspection Notification/Inspection and Test Report/Inspection and Test Plan (ITP)
Storage and Preservation Guide
Material Certificates/Special Tools List
Training Program
Final Data Book Index/Final Data Book
Basic Design
Overall/Each Panel Layout (outline dimensions with tolerances & clearances for front & side view)
General Arrangement Diagram
Single Line Diagram
Heat Dissipation Calculation
Busbar Sizing Calculation
AC/DC Load Consumption List with load profile
CTs & PTs Calculation
Fuse Sizing Calculation
Foundation and Cable Entrance Layout (Opening with Tolerances & Clearances)
Loading Data (Including Static and Dynamic Load)
Busduct/Power Cable Connection Compartment Details
Main & Branch Busbar Arrangement Details
Tightness Table
AC,DC Distribution
Switchgear Data Sheet
Bill of Materials/Parts List for Each Panel
Protection Relay Manuals (Type, Curve & Setting Range)/Technical Catalogues
Relay Setting and Coordination Report & Table and Data Entry
Communication Ports Specification
Registery Map for Protection Relay & Measurement Devices
Installation Operation,Maintenance Manual (Fault Finding & Trouble Shooting Manual)
Commissioning Spare Part List/Two Years Spare Part List
Type Test Reports & Certificate
Detail Design
Schematic Wiring Diagram for Incoming/Coupling Feeder
Typical Schematic Wiring Diagram for Outgoing Feeder
Logic Diagram
Interlock List & Sequence & Interlock List & Sequence
Terminal Diagram (with Size, Arrangements & Location)
Inter Panel Wiring & Terminal Diagram
Name Plate & Label Data Arrangements
Mimic Diagrams (on the Cubicle)
Communication Ports Diagram for Protection Relay & Measurement Devices
Routine Test Reports

[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content_no_spaces” woodmart_stretch_content=”section-stretch-content-no-pd” woodmart_css_id=”64a5af7baade4″ responsive_spacing=”eyJwYXJhbV90eXBlIjoid29vZG1hcnRfcmVzcG9uc2l2ZV9zcGFjaW5nIiwic2VsZWN0b3JfaWQiOiI2NGE1YWY3YmFhZGU0Iiwic2hvcnRjb2RlIjoidmNfcm93IiwiZGF0YSI6eyJ0YWJsZXQiOnt9LCJtb2JpbGUiOnt9fX0=” mobile_bg_img_hidden=”no” tablet_bg_img_hidden=”no” woodmart_parallax=”0″ woodmart_gradient_switch=”no” woodmart_box_shadow=”no” wd_z_index=”no” woodmart_disable_overflow=”0″ row_reverse_mobile=”0″ row_reverse_tablet=”0″][vc_column][vc_single_image image=”10182″ img_size=”full” alignment=”center” parallax_scroll=”no” woodmart_inline=”no”][/vc_column][/vc_row]