[vc_row full_width=”stretch_row_content_no_spaces” woodmart_stretch_content=”section-stretch-content-no-pd” woodmart_css_id=”64a5ae2d00f7e” responsive_spacing=”eyJwYXJhbV90eXBlIjoid29vZG1hcnRfcmVzcG9uc2l2ZV9zcGFjaW5nIiwic2VsZWN0b3JfaWQiOiI2NGE1YWUyZDAwZjdlIiwic2hvcnRjb2RlIjoidmNfcm93IiwiZGF0YSI6eyJ0YWJsZXQiOnt9LCJtb2JpbGUiOnt9fX0=” mobile_bg_img_hidden=”no” tablet_bg_img_hidden=”no” woodmart_parallax=”0″ woodmart_gradient_switch=”no” woodmart_box_shadow=”no” wd_z_index=”no” woodmart_disable_overflow=”0″ row_reverse_mobile=”0″ row_reverse_tablet=”0″][vc_column][vc_single_image image=”10240″ img_size=”full” alignment=”center” parallax_scroll=”no” woodmart_inline=”no”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text woodmart_inline=”no” text_larger=”no”]
| شرکت نیک نیرو توسعه فردا در زمینه طراحی و تامین انواع سوئیچگیرهای برق در سطوح ولتاژ 3.3KV,6KV,6.6KV,11KV,12KV,17.5KV,20KV,33KV و 34.5KV مشغول به فعالیت می باشد. |
| این شرکت علاوه بر طراحی مدارک مربوط به انواع تابلوهای صنایع وزارت نیرو، پروژه های صنایع نفت، گاز و پتروشیمی را نیز انجام می دهد برخی از مدارکی که توسط این شرکت طراحی می گردند، به شرح ذیل می باشند: |
| MV PART |
| General |
| Vendor Print Index & Schedule |
| Quality Control Plan/Quality Control System |
| Packing/Painting/Shop test & Inspection Procedure/Site Acceptance Tests Procedure |
| Sub Vendor List |
| Time Schedule/Progress Report |
| Inspection Notification/Inspection and Test Report/Inspection and Test Plan (ITP) |
| Storage and Preservation Guide |
| Material Certificates/Special Tools List |
| Training Program |
| Final Data Book Index/Final Data Book |
| Basic Design |
| Overall/Each Panel Layout (outline dimensions with tolerances & clearances for front & side view) |
| General Arrangement Diagram |
| Single Line Diagram |
| Heat Dissipation Calculation |
| Busbar Sizing Calculation |
| AC/DC Load Consumption List with load profile |
| CTs & PTs Calculation |
| Fuse Sizing Calculation |
| Foundation and Cable Entrance Layout (Opening with Tolerances & Clearances) |
| Loading Data (Including Static and Dynamic Load) |
| Power Cable Connection Compartment Details |
| Main & Branch Busbar Arrangement Details |
| Tightness Table |
| AC,DC Distribution |
| Switchgear Data Sheet |
| Bill of Materials/Parts List for Each Panel |
| Protection Relay Manuals (Type, Curve & Setting Range)/Technical Catalogues |
| Relay Setting and Coordination Report & Table and Data Entry |
| Communication Ports Specification |
| Registery Map for Protection Relay & Measurement Devices |
| Installation Operation,Maintenance Manual (Fault Finding & Trouble Shooting Manual) |
| Commissioning Spare Part List/Two Years Spare Part List |
| Type Test Reports & Certificate |
| Detail Design |
| Schematic Wiring Diagram |
| Logic Diagram |
| Interlock List & Sequence & Interlock List & Sequence |
| Terminal Diagram (with Size, Arrangements & Location) |
| Inter Panel Wiring & Terminal Diagram |
| Name Plate & Label Data Arrangements |
| Mimic Diagrams (on the Cubicle) |
| Communication Ports Diagram for Protection Relay & Measurement Devices |
| Routine Test Reports |
[/vc_column_text][/vc_column][/vc_row][vc_row full_width=”stretch_row_content_no_spaces” woodmart_stretch_content=”section-stretch-content-no-pd” woodmart_css_id=”64a5ae2d00f7e” responsive_spacing=”eyJwYXJhbV90eXBlIjoid29vZG1hcnRfcmVzcG9uc2l2ZV9zcGFjaW5nIiwic2VsZWN0b3JfaWQiOiI2NGE1YWUyZDAwZjdlIiwic2hvcnRjb2RlIjoidmNfcm93IiwiZGF0YSI6eyJ0YWJsZXQiOnt9LCJtb2JpbGUiOnt9fX0=” mobile_bg_img_hidden=”no” tablet_bg_img_hidden=”no” woodmart_parallax=”0″ woodmart_gradient_switch=”no” woodmart_box_shadow=”no” wd_z_index=”no” woodmart_disable_overflow=”0″ row_reverse_mobile=”0″ row_reverse_tablet=”0″][vc_column][vc_single_image image=”10179″ img_size=”full” alignment=”center” parallax_scroll=”no” woodmart_inline=”no”][/vc_column][/vc_row]